System Specs

Special AI is an IBM Business Partner

Zimbra System Specifications

Primary Mailbox Cluster
PlatformCluster of dedicated IBM System x3630 M3 servers (specs below are per-server)
ArchitectureDual Intel Xeon 6-core 3.06 GHz HT CPU 12MB L3 cache (24 logical CPUs) 1333 MHz FSB
System Bus6.4GTps Quick Path Interconnect
MemoryAt least 36 GB PC3-10600 ECC DDR3 RAM @ 1333 MHz
Internal Storage3 independent RAID1 arrays (15k RPM hot-swap SAS drives) with shared hot spare
Power & CoolingRedundant hot-swap
SAN Interface6 Gbps SAS HBAs with iSCSI backup
On-Line Storage
PlatformIBM System Storage DS3500
RAID ControllersDual active hot-swap each with 2 GB battery-backed cache
Performance40k IOPS up to 4000 MB/s
Power & coolingDual redundant, hot-swap components connected to discrete 208v AC circuits
Native Capacity192 TB
Primary Host InterfaceDual 6 Gbps Serial Attached SCSI (SAS)
Secondary Host InterfaceDual 4 Gbps iSCSI; dedicated 68 Gbps non-blocking Ethernet switch fabric
Primary Storage ArraysEXT4 on RAID-10; 15k RPM 6 Gbps drives with hot spares
Secondary Storage ArraysXFS on RAID-10; 10k RPM 6 Gbps drives with hot spares
Manufacturer SupportIBM 24x7x365 on-site service; 4 hour response
Inbound Internet Mail Exchangers
PlatformDedicated IBM System x3550 M3 servers (specs below are per-server)
ArchitectureDual Intel Xeon 6-core 2.66 GHz HT CPU 12MB L3 cache (24 logical CPUs) 1333 MHz FSB
System Bus6.4GTps Quick Path Interconnect
MemoryAt least 20 GB PC3-10600 ECC DDR3 RAM @ 1333 MHz
Internal Storage2 independent RAID1 arrays (10k RPM hot-swap SAS drives) with shared hot spare
Power & CoolingRedundant hot-swap
Network
DNSDynect Anycast; replication across 17 global data centers guarantees 100% availability plus advanced failover and load balancing capabilities
Data Centers3 primary and 6 supporting facilities, geographically distributed throughout the United States. No two data centers are owned/operated by the same company. All three primary facilities are SAS70 certified.
Internet Access7 upstream providers total; dual-active redundant 100 Mbps uplinks at vis0; redundant 100 Mbps uplinks at hud0 and sea0; BGP4 routing and failover between all three primary data centers
PeeringDirect peering from our cage at 60 Hudson Street to critical carriers and content providers improves network performance and reliability. The carrier hotel at 60 Hudson Street in downtown Manhattan is generally considered the most important interconnect facility in the world and the center of international telecommunications.